Quick Answer
ADS1220IPWR is Texas Instruments' 24-bit delta-sigma analog-to-digital converter in a sixteen-pin TSSOP package, supplied in tape-and-reel presentation. It integrates a programmable gain amplifier, reference and excitation current sources for sensor measurement. Select it against the complete measurement sequence, not merely the headline resolution or maximum conversion rate.
The key purchasing distinction is between a component specification and a verified instrument result. A converter's output word length does not establish usable resolution or final accuracy. Before accepting an offer or alternate, define the sensor interface, operating configuration and evidence that will demonstrate acceptable performance on the intended board.
- Keep ADS1220IPWR and the PW package identity visible throughout quotation and receiving.
- Specify required measurement quality and channel update time separately.
Key Specifications
The input multiplexer supports two differential or four single-ended inputs. The family reaches up to 2,000 samples per second and provides programmable gain up to 128. Its simultaneous rejection of 50 Hz and 60 Hz interference is associated with the 20-samples-per-second setting; that property must not be assumed at every selected data rate.
TI lists IPWR as TSSOP16 with 2,500 devices per large tape-and-reel package and an operating temperature range of minus 40 to plus 125 degrees Celsius. A required order quantity need not equal that carrier quantity, but any alternative presentation should be stated and approved explicitly.
- Review the input and common-mode restrictions for the selected PGA configuration.
- Choose the reference arrangement and excitation settings from the actual sensor circuit.
- Assess noise and effective resolution at the intended gain and data rate rather than equating 24-bit coding with 24-bit accuracy.
Where to Use This Part
For a resistance-temperature measurement channel, begin with a connection diagram showing the sensor leads, reference path and protection. Add the intended measurement sequence to that drawing. Engineering can then check whether current routing, settling and conversion timing fit the required update interval before purchasing commits to a production build.
A multichannel instrument needs a schedule, not just a rate setting. List each channel, its configuration changes and the point at which a valid reading is consumed by software. Include diagnostic measurements in the same schedule. This recommended worksheet makes it easier to detect an unrealistic assumption that every connected sensor receives the converter's maximum output rate simultaneously.
Develop an acceptance record that stores raw codes and register settings together. Repeat selected tests with representative sensor wiring and nearby digital activity. Keep the calibration state explicit so that a comparison between device lots does not accidentally compare different software corrections. The goal is reproducible evidence about the assembled measurement path, rather than an impressive-looking average from an undocumented setup.
- Temperature instruments: define required accuracy, wiring arrangement and the slowest acceptable update before selecting conversion settings.
- Bridge measurements: examine excitation and reference relationships together with the sensor output range.
- Process-monitoring prototypes: include communication interruptions and restart behavior in the test sequence so configuration recovery is exercised.
Pricing and Lead Time
Request ADS1220IPWR using the full code, quantity, destination and required delivery schedule. If the production line needs an intact manufacturer reel, say so in the RFQ. If a smaller presentation is acceptable, ask the supplier to describe it rather than assuming every quoted quantity arrives in the same packaging.
Obtain a written response that distinguishes offered material from material expected later. Record price currency, quotation validity and the quantity attached to each delivery statement. Separate the evaluation lot from production releases when their commercial or packaging requirements differ. This guide provides no verified seller inventory or fixed delivery promise for a particular purchase.
Receiving requirements should identify the complete part number and the records to retain with the lot. Agree how discrepancies between the quotation, label and supplied quantity will be reviewed. A clear hold-and-review process prevents an unexplained carrier substitution from entering assembly simply because the package itself appears familiar.
For scheduled production, make the quotation review visible to both firmware and hardware owners. A proposed converter change can create software qualification work as well as component work. Record which design revision the purchase supports and whether any deviation has been approved. The resulting order can then be assessed against a controlled configuration instead of a generic request for a 24-bit ADC.
Common Alternatives
ADS1220IPW is identified by TI as another carrier option for the same PW package. That is a different purchasing question from selecting a converter in another package or family. Confirm the exact ordering identity, feeder arrangements and handling requirements before accepting a carrier change for an automated assembly line.
For another ADC, compare input topology, usable common-mode range, reference requirements, gain settings, conversion timing and the digital interface. Include the register map and startup behavior in the review. Similar resolution and pin count do not demonstrate that existing firmware can operate a proposed part correctly.
Require the alternate evaluation to use the original channel schedule and acceptance limits. Retain any changed filter settings or calibration method with the results. If a candidate meets only some operating modes, document those limits before the purchasing team negotiates quantities. The most useful comparison is the cost and schedule of an approved measurement solution, including necessary engineering effort, rather than the unit price of an unqualified substitute.
FAQ
Does 24-bit output establish 24-bit measurement accuracy?
No. Noise, gain, reference quality and the complete sensor circuit affect usable resolution and accuracy. Evaluate the relevant noise data and test the assembled channel.
Can the fastest data rate also be assumed to reject both mains frequencies?
No. The simultaneous 50 Hz and 60 Hz rejection cited by TI applies to the documented 20 SPS setting. Select and verify the filter configuration for the application.
Is ADS1220IPW the same purchasing presentation as ADS1220IPWR?
No. TI identifies IPW as tube presentation and IPWR as tape and reel for the PW package. Confirm what the supplier will deliver and what the assembly process accepts.
Request a quotation for ADS1220IPWR and your required quantities
Sources
- TI ADS1220IPWR ordering and packaging details (checked 2026-10-02)
- TI ADS1220 datasheet SBAS501D, Rev. D (checked 2026-10-02)