Quick Answer
ISO1640DWR is a bidirectional I2C isolator with bidirectional clock and data paths in a 16-pin wide-body SOIC. It is worth evaluating when an industrial sensor or controller bus must cross an isolation boundary while preserving behaviours such as clock stretching. The complete DWR ordering code identifies the package to source; another ISO164x family member can have a different channel arrangement.
The procurement discussion should begin with the bus, not just a voltage rating. List every controller and peripheral, the intended clock frequency, pull-up supplies and the permitted startup sequence. Note whether any peripheral can hold the clock low. An ordinary fixed-direction digital isolator may look similar in a component search but does not answer the same interface problem. A clear requirements note makes that distinction visible before commercial offers arrive.
Key Specifications
TI describes ISO1640 with bidirectional SDA and SCL and signalling up to 1.7 MHz. The two sides have different supply and loading specifications. These asymmetries should be preserved in design records so an engineer reviewing a revised board does not assume that the two local buses are electrically identical.
Pull-up selection involves the sink capability, logic thresholds, bus capacitance and timing requirements of all connected devices. Preserve the calculation and measured rise times with the qualification evidence. A device's maximum operating frequency does not mean every bus built with it can achieve that rate. For purchasing purposes, refer to the tested configuration and approved part identity, not an isolated headline value.
- Check the side-one supply range of 3 V to 5.5 V and side-two range of 2.25 V to 5.5 V.
- Review the stated maximum capacitive loads of 80 pF on side one and 400 pF on side two against the actual local connections.
- Match the DW 16-pin footprint, pin assignments and insulation requirements to the released PCB design.
Where to Use This Part
Evaluation opportunities include isolated sensor interfaces, power-management communication and modular industrial equipment. The purpose is to maintain a suitable local I2C interface on each side of the barrier, while the system provides the necessary power and protection arrangements.
The manufacturer's hot-swap feature description should be read with the complete interface design. It does not qualify every connector sequence or cable arrangement. Include abnormal cases in the evaluation: a peripheral held in reset, one side powered down, and interrupted transactions. Record the controller's response and any recovery action. These observations help a maintenance team distinguish a communication issue from a purchasing error when equipment is serviced years later.
- For a sensor module, test the full address set and confirm that all required transactions survive the intended power sequence.
- For a power-management bus, document clock stretching, timeout handling and any required recovery sequence after a stuck line.
- For a removable module, assess insertion and removal using the actual connector and board supply behaviour.
Pricing and Lead Time
A complete RFQ identifies ISO1640DWR, quantity, destination, need date and the approved package. Add required documentation and whether the material is for evaluation or released production. When requesting a proposed alternate, provide the bus requirements rather than asking only for another isolated I2C part.
Ask the supplier to state lot and carrier information in the written offer. If several lots are proposed, decide whether they need separate receiving records. Keep the original labels and any approved documentation associated with the inventory after partial reels are issued to assembly. Losing that connection makes later investigation harder even when the initial shipment was properly documented.
Price and delivery must come from current quotations. The part's manufacturer classification is not evidence of stock held by a particular seller. Compare the proposed quantity, offer validity and delivery basis consistently. Include your internal qualification time when considering a changed device, because a commercial promise to provide components does not finish the engineering work required to release them.
Common Alternatives
The first alternative question is clock direction. ISO1640 is not functionally identical to every member of its family. A design requiring a peripheral to stretch the clock must preserve an appropriate return path; another arrangement may suit only a different bus architecture.
Compare each candidate's local-bus voltage limits, low-level output behaviour, input thresholds, sink capability and capacitance limits. Also review idle behaviour, power loss, startup and interaction with other buffers. Several individually valid interface components can still create a problematic chain if their threshold assumptions conflict. That issue should be resolved with a documented circuit review and representative measurements.
A redesigned system may move the isolation boundary elsewhere, use a different communication protocol or digitise and process sensor data locally. Those options change software and board responsibilities as well as component selection. Keep them as a separate design activity. For an unchanged board, purchasing should request the exact approved orderable and submit any alternate with its evidence, known differences and required qualification tasks clearly listed.
FAQ
Why does bidirectional clock support matter?
Some I2C peripherals extend a clock period by holding SCL low. The system must support the behaviour it actually uses. Review the isolator channel direction and controller timeout handling together rather than assuming every isolated I2C device behaves alike.
Can both sides use identical pull-up resistors?
Possibly, but only after calculating and testing both local buses. Their capacitance, voltage and sink-current limits may differ. Select values from the connected devices and timing requirements rather than copying a resistor from one side to the other.
Does this article confirm medical suitability?
No. ISO1640DWR is a component for interface evaluation. Any medical application needs qualification of the complete board and system, including power, insulation, patient connections where relevant, and the intended operating and fault conditions.
Request an RFQ review for ISO1640DWR
Sources
- Texas Instruments ISO1640 product information (checked 2026-10-02)
- Texas Instruments ISO1640DWR ordering and package information (checked 2026-10-02)