Quick Answer
OPA4187ID is the 14-pin SOIC, tube-packed quad version of Texas Instruments OPAx187 precision amplifier family. TI marks this complete orderable ACTIVE. Its documented applications include analog input modules, pressure and flow transmitters, and test and measurement. Evaluate it where a slowly varying signal requires careful control of amplifier offset and drift, while checking the entire measurement chain.
The selection question is the accuracy required at the system output after environmental variation, calibration and loading are considered. Four amplifiers in one package can simplify a channel arrangement, but they do not establish a finished instrument accuracy rating. Prepare a channel diagram, identify every gain and offset contribution, and connect the component decision to a measurable acceptance plan.
Key Specifications
Use the electrical tables rather than combining unrelated headline numbers. TI distinguishes a typical offset-drift figure from its maximum limit. Keep the test temperature, supply, common-mode voltage and load with each copied parameter. The same discipline should apply when comparing another amplifier: a typical value from one part is not directly comparable with a guaranteed limit from another.
An illustrative error allocation makes the scale easier to evaluate. At a circuit noise gain of 100, an input-referred error of 10 microvolts contributes 1 millivolt at the output. This is arithmetic for an assumed circuit, not a claim about a completed sensor module. Add the effects of resistors, reference, sensor and acquisition stage before deciding whether calibration can meet the specification.
- Supply and output: operation spans 4.5 V to 36 V total supply, with rail-to-rail output capability under the applicable load conditions.
- Input limitation: the common-mode range includes the negative rail and extends only to 2 V below the positive rail in the electrical tables.
- Precision: the high-voltage table lists 10 microvolts maximum offset at 25 degrees Celsius and drift of 0.001 typical, 0.015 maximum microvolts per degree Celsius.
- Exact package: OPA4187ID uses 14-pin SOIC D, with a specified temperature range of minus 40 to plus 125 degrees Celsius.
Where to Use This Part
TI identifies industrial measurement applications for this family. The workflows below are engineering evaluation suggestions within those categories, rather than claims about a customer installation or an approved instrument.
For a multichannel analog input module, begin with a channel map showing sensor range, gain, reference and acquisition timing. Define the required behavior when one input is disconnected or overdriven while another is being measured. Exercise these cases during qualification and retain a channel-by-channel results table. A single successful reading at room temperature does not cover the range of field conditions.
For a pressure or flow transmitter, separate initial calibration error from changes after calibration. Record zero and span at the chosen calibration point, then repeat measurements across the intended environmental envelope. Keep the same sensor excitation and measurement procedure across trials. When an error appears, compare raw channel readings with the corrected output before changing either hardware or software coefficients.
For a test fixture, make repeatability visible in the acceptance procedure. State warmup conditions, connection sequence, reference source and number of observations. Preserve raw measurements alongside the final pass decision. That record helps distinguish a component change from a change in the way the fixture was exercised.
- Analog input modules: evaluate each signal path and the behavior of neighboring channels during switching and fault conditions.
- Pressure, flow and test instrumentation: qualify calibration stability and usable range against the instrument requirement.
Pricing and Lead Time
Use OPA4187ID as the RFQ line item and attach the required quantity, carrier preference, delivery destination and assembly schedule. Ask for written confirmation of the exact offered manufacturer code, price and delivery terms. Neither the lifecycle label nor this article establishes a supplier quantity or fulfillment commitment.
If the component supports a calibrated product, include any change-control and traceability requirements in the purchasing package. Decide whether a material change requires a limited verification build or a broader release review. Have engineering define the acceptance measurements before material arrives so receiving staff are not asked to infer analog performance from a package label.
For recurring builds, retain a record linking the approved bill of materials, received lot and calibration procedure revision. Compare quotations on the same scope of documentation and inspection. Resolve partial deliveries and carrier changes explicitly rather than allowing them to create undocumented exceptions during assembly. Commercial confirmation and technical approval should both be complete before committing material to a controlled build.
Common Alternatives
TI lists OPA4187IDR as another carrier option for the same package, using tape-and-reel packing. Preserve the complete orderable in the purchase record and check assembly handling requirements before approving that option.
For a different amplifier, compare input headroom, offset limits, drift limits, noise, settling, supply requirements and output loading in the actual circuit. Changing the number of amplifiers per package can also change routing and test access. Rank candidates by the measurement requirement they satisfy, then repeat the relevant calibration and environmental checks. A shared package outline or a stronger headline specification does not by itself establish equivalence.
FAQ
Is OPA4187ID rail-to-rail at both its input and output?
No. TI describes rail-to-rail output, while the input common-mode range has a positive-rail headroom requirement. Check both input voltages throughout the signal cycle and during startup.
Does zero-drift operation eliminate system calibration?
No. Calibration decisions depend on the entire error budget, including the sensor, reference and resistors. Define accuracy over the intended conditions and verify the finished measurement chain before choosing a calibration interval.
Is OPA4187IDR the same purchasing line as OPA4187ID?
They are separate orderable codes with different carrier formats. TI presents IDR as the tape-and-reel option. Keep the accepted code and handling arrangement explicit in the quotation and assembly records.
Request an OPA4187ID quotation for your measurement design
Sources
- TI OPA4187ID orderable details (checked 2026-10-10)
- TI OPAx187 precision amplifier datasheet, SBOS807E (checked 2026-10-06)