TMUX1108PWR: Complete Sourcing Guide & Price 2026

Evaluate TMUX1108PWR for multiplexed precision measurements with leakage, settling, input protection and medical-system qualification considerations.

Quick Answer

TMUX1108PWR is an eight-to-one precision analog multiplexer in a 16-pin TSSOP package. It can be considered when several low-voltage measurement channels share one signal path, such as a precision amplifier or ADC input. For procurement, specify the complete orderable and preserve the signal-voltage, leakage and timing requirements established by engineering. The number of channels alone does not define a suitable alternate.

This part is relevant to industrial instruments and medical equipment development, but those contexts do not turn it into a certified medical subsystem. Any medical use requires qualification of the board and finished device. The sourcing file should identify whether the multiplexer routes sensor outputs, calibration references or another low-voltage signal. Each use puts different emphasis on leakage, channel settling, protection and the consequences of selecting the wrong input.

Key Specifications

TI identifies the TMUX1108 as a single-channel eight-to-one switch arrangement with bidirectional signal paths. The device supports a wide low-voltage supply range, and the manufacturer lists break-before-make switching. The ordering page confirms the PW package with 16 pins for TMUX1108PWR.

Very small current specifications deserve attention to their conditions. A room-temperature typical leakage number is not an all-temperature guarantee for every assembled board. PCB contamination, connector leakage and external protection can also affect a high-impedance measurement. Ask engineering to define the full-channel acceptance requirement. Purchasing should preserve the exact component and package that formed the basis of that qualification, not substitute solely from a catalogue's channel-count filter.

  • Confirm the specified supply and permitted analog signal range for the intended single-supply or supported dual-supply configuration.
  • Review on-state resistance, leakage and charge injection under the actual voltage and temperature conditions, distinguishing typical values from guaranteed limits.
  • Check the logic thresholds, enable behaviour and channel-address truth table against the controller and startup sequence.

Where to Use This Part

Potential evaluation uses include selecting precision sensor signals, switching calibration references and multiplexing low-voltage monitoring channels. The useful question is how the entire acquisition chain behaves after a channel change, rather than how quickly a digital address pin can switch.

Keep the actual channel scan order in the test plan. Alternating between near-zero and near-full-scale signals can reveal behaviour that a series of similar inputs conceals. Test any proposed external protection network with the same care, because it can change settling and leakage. These recommendations describe a validation approach; they do not claim that a particular offered lot or end product has already achieved a specified measurement performance.

  • For high-impedance sensors, examine leakage errors and the additional settling time introduced by the source impedance.
  • For an ADC input, verify acquisition timing after a large step between adjacent channels and decide whether an initial conversion must be discarded.
  • For a medical instrument, include fault cases such as an incorrect channel selection or an input driven outside its permitted range in system qualification.

Pricing and Lead Time

An RFQ should request TMUX1108PWR, quantity, destination, assembly schedule and required carrier format. Identify any approved constraints on date codes or lot mixing. If the application has a controlled component list, ask that all deviations be presented separately rather than embedded in a quotation note that receiving staff may not see.

Request the records needed to connect the supplier's offer to the delivered material. Label photographs can support identification, but they are only part of an evidence package. Define what receiving will compare and what engineering will test before release. For low-leakage applications, careful handling and assembly cleanliness are also relevant to the final result, so avoid reducing the entire quality discussion to the component marking.

Use a current dated quote for price and delivery. State whether the demand is a prototype evaluation, pilot build or released production order. This makes it easier to compare suitable carrier options and prevents an estimated future volume from being mistaken for a binding purchasing commitment.

Common Alternatives

Alternative review should cover the signal range before resistance or price. A switch with a superficially similar eight-to-one configuration may use different supply arrangements, analog voltage limits or protection structures. Those differences can affect both normal measurements and behaviour when part of the system is unpowered.

Compare leakage across temperature, charge injection, capacitance, on-resistance variation and switching sequence in addition to pinout. For a precision measurement, the most attractive minimum resistance value may be less important than repeatable settling or a small error with a high-impedance source. Define which limits actually control the instrument's result.

A redesign can place buffers before or after the multiplexer, change the sampling order or use additional conversion channels. Each choice redistributes cost, power and test complexity. For a released product, however, preserve the approved acquisition chain until an alternate has passed a documented review. Keep the proposed substitute's exact orderable, test results and board revision together. That record lets sourcing support continuity without silently altering the measurement assumptions used by manufacturing and service teams.

FAQ

Does fail-safe logic protect every analog input condition?

Do not assume that. Read the manufacturer definitions and the analog-pin limits separately. Control-pin behaviour during power sequencing does not establish unlimited tolerance for voltages applied to the signal pins.

Why does an ADC reading change after switching channels?

The signal path and ADC input need time to settle after a new source is selected. Source impedance, capacitance, charge transfer and scan sequence can all matter. Measure the complete acquisition chain with representative input steps.

Can the same multiplexer be used in a medical product?

It may be evaluated as a component, but suitability requires qualification of the complete design for its intended medical use. This includes relevant electrical protection, measurement reliability and fault handling; the part number alone establishes none of those outcomes.