Quick Answer
TPS63031DSKR is TI's fixed 3.3 V buck-boost converter in a ten-pin DSK WSON package. It can regulate through the transition where the input moves above or below the output. This makes it a candidate for battery-powered products whose source voltage crosses the required rail during discharge.
The most important sourcing distinction is between switch current and usable output current. The family title refers to 1 A switches; that does not establish a 1 A output across the entire battery range. Qualify the complete load profile and lowest intended input before treating an offer for this device as a solution to the power requirement.
- Preserve the TPS63031 fixed-output identity and DSKR package/carrier code.
- Assess output capability at the minimum battery voltage, including peak loads and source impedance.
Key Specifications
TI specifies an input range of 1.8 to 5.5 V and identifies DSKR as WSON10 on tape and reel. The small leadless package requires the correct land pattern and assembly process. Consult the DSK drawing rather than selecting a footprint from a broad QFN search result.
The family includes both adjustable and fixed-output versions. The application schematic must follow the selected device's feedback arrangement, not merely a similar circuit found in a family overview. Keep the controlled schematic with the exact converter code so that an ordering change cannot silently change the rail configuration.
- Load capability: TI gives different output-current conditions for step-down and boost operation; use the relevant curves for the actual input and output.
- Operating mode: power-save operation can be disabled for fixed-frequency operation; choose the mode from efficiency and noise requirements.
- Shutdown: the documented load-disconnect feature is relevant to standby architecture, but evaluate all other paths that could energize the load.
Where to Use This Part
A portable instrument may draw little current between measurements and a substantial burst while processing or transmitting. Build a time-based load profile that includes both states. Test the rail during that burst at the weakest allowed battery condition. The design must be judged by the event that threatens regulation, not just by average consumption.
Source impedance matters when the battery is nearly depleted. A laboratory supply connected with short leads can conceal voltage collapse that appears with the intended cells, connectors and protection. Repeat the qualification with a representative source model or battery arrangement, and record the conditions that triggered any reset or undervoltage response.
The converter's mode choice can affect noise-sensitive measurements. Compare rail waveforms and measurement results with power-save enabled and disabled under the relevant load states. The preferred setting should follow measured system behavior, with any firmware-controlled transition included in the test plan.
- Battery-powered sensors: verify acquisition quality during the converter mode changes that occur in the actual duty cycle.
- Handheld controllers: test user-driven peak loads while input voltage passes through the nominal output level.
- Portable communications products: examine short load bursts, recovery time and the energy consumed between transmissions.
Pricing and Lead Time
Send an RFQ for TPS63031DSKR with the complete number, planned quantities and required carrier presentation. TI lists the DSKR ordering option as a large tape-and-reel pack. State any production feeder requirements, accepted lot splits and receiving documentation needs directly in the request.
A supplier should identify the exact offered part rather than shortening it to TPS6303x or buck-boost regulator. If the reply proposes TPS63030 or another device, put it into an engineering review queue with its full code. The buyer should not resolve an adjustable-versus-fixed-output change by interpreting a generic commercial description.
Compare written quotations by price basis, currency, validity and quantity-linked delivery dates. Ask whether the proposed schedule concerns dispatch or arrival, and record any assumptions about packaging. Separate sample needs from production quantities so an engineering evaluation does not create an implied approval for the full build.
When material arrives, match the purchase order to the package label and preserve the lot association with assembled boards. Any approved carrier deviation should be visible to receiving and manufacturing. These controls support a repeatable purchase; they do not demonstrate that a particular seller currently has a qualified lot ready for your project.
Common Alternatives
TPS63030 is the adjustable member of the documented family, while TPS63031 provides the fixed-output arrangement. That relationship makes it a sensible engineering comparison, but the feedback network and complete application circuit require review. Identify any changed passive components and update the schematic before approval.
For a different buck-boost converter, compare the minimum-input load capability, startup behavior, mode control, shutdown paths and permitted passive components. Look at current limits in context: switch, inductor and output current are not interchangeable quantities. Use the same battery and load profile for both evaluation boards.
A redesign may reduce standby consumption or improve peak-load performance, but those benefits need measurement on the intended hardware. Include layout effort, thermal assessment and interference testing in the decision. A quotation becomes an actionable alternate only when its complete device identity is tied to an approved design and acceptance plan.
FAQ
Does the 1 A switch description mean 1 A output is guaranteed?
No. Available output depends on input voltage, conversion ratio, current limits and thermal conditions. Use the datasheet operating curves and validate the lowest-input load case.
Is TPS63031 the adjustable-output device?
The documented TPS63031 arrangement is fixed at 3.3 V. TPS63030 is the adjustable family member; changing between them requires checking the feedback circuit and design record.
Why test with the intended battery arrangement?
Battery impedance, wiring and protection can cause additional input droop during a load burst. A stiff laboratory supply may hide that behavior and overstate the product margin.
Request a quotation for TPS63031DSKR with your build requirements
Sources
- TI TPS63031DSKR ordering details (checked 2026-10-02)
- TI TPS6303x datasheet SLVS696D (checked 2026-10-02)