Quick Answer
XTR116U/2K5 is a Texas Instruments current-loop transmitter orderable for circuits that produce 4-mA to 20-mA analog output. The family includes a 4.096-V reference and a 5-V regulator for external circuitry. This makes the part relevant to evaluating loop-powered sensor transmitters, provided the whole circuit fits the available current and voltage budgets. Preserve the slash and packaging suffix in the procurement record.
The exact suffix is especially important here. At the source check for this guide, TI's XTR116U ordering page identified that tube orderable as obsolete and pointed to XTR116U/2K5 as an active option. That observation concerns manufacturer ordering status, not seller availability. Recheck it before purchase. It illustrates why a family page and a shortened RFQ description can conceal a meaningful packaging or lifecycle distinction.
Key Specifications
The XTR116 family is designed for two-wire current-loop applications. The manufacturer specifies a loop supply range from 7.5 V to 36 V and operation from minus 40 to plus 85 degrees Celsius. The reference voltage differs from the related XTR115, making the reference function an important identity check.
A loop is a complete electrical path. Available voltage must support the transmitter, cable, receiver burden and any protection or barriers in that path. Ask engineering to document those assumptions. Procurement can then obtain the specified component without accidentally accepting an architecture whose loop requirements differ from those of the installed equipment.
- Include the 4.096-V reference in the sensor excitation and calibration calculation rather than treating it as interchangeable with another reference value.
- Account for all external circuitry powered from the device when calculating operation at the low end of the output-current range.
- Verify the eight-pin SOIC connections, including the current-return path described by the manufacturer, against the approved schematic.
Where to Use This Part
Useful evaluation settings include pressure transmitters, temperature measurement and other industrial sensors that report an analog measurement through a current loop. The component is a building block; signal conditioning, protection, calibration and enclosure design remain part of the transmitter development.
During validation, check the low, middle and high points of the output span as well as startup and abnormal supply conditions. A prototype that works at 20 mA may reveal a power-budget problem near 4 mA. Document the observed behaviour with the board revision and calibrated test setup. For field replacement, also record whether the original equipment uses a separately powered transmitter, because a similar output range alone does not mean the same wiring architecture.
- For a pressure sensor, budget excitation and conditioning current before selecting additional digital functions.
- For a temperature transmitter, review the input conditioning and error allocation across the sensor, reference and output conversion.
- For an installed process loop, measure the available operating margin with the actual receiving instrument and cable arrangement.
Pricing and Lead Time
Write XTR116U/2K5 in full on the RFQ, quotation comparison and purchase order. State quantity, intended carrier, destination and the assembly need date. If the ERP system transforms punctuation, preserve a separate manufacturer-number field or supporting note so the slash is not lost when the order reaches the supplier.
Request a commercial response that identifies the proposed lot and packaging. A quoted tube variant, cut tape or re-reel should be visible as a specific proposal with the handling and traceability requirements reviewed. Do not assume that a packaging change is either automatically prohibited or automatically approved; assess it against the actual assembly and quality process.
No current price or dispatch commitment is established here. Obtain a dated quote and ask what its schedule means. For a long-running industrial product, add a periodic review of exact-orderable lifecycle information to the sourcing file. That process is more useful than assuming that an active family heading guarantees all historical carrier versions remain in production.
Common Alternatives
Alternative review should begin with the reference and power architecture. TI identifies XTR115 with a 2.5-V reference, while XTR116 uses 4.096 V. A circuit built around one reference can need recalculation if moved to another, even when the basic current-loop function looks similar.
Compare input scaling, regulator capability, quiescent demand, output-current control and permitted supply conditions. Review the behaviour of the entire transmitter at the minimum output current. Where an alternative changes the external component network, update the calibration procedure and manufacturing test limits before it reaches the production line.
A different loop-transmitter architecture may offer features useful to a new design, but an installed instrument also has wiring, compliance and maintenance expectations. Keep repair sourcing aligned to the released configuration unless the design authority approves a change. Record the exact accepted orderable and packaging options, the evidence supporting them and any remaining restrictions. The purchasing team can then act on a clear specification without turning a replenishment exercise into an undocumented redesign.
FAQ
Why is XTR116U/2K5 written with a slash?
It is part of the complete manufacturer ordering identifier. Preserve it when transferring information between spreadsheets, ERP records and supplier requests. The website slug may replace punctuation, but the manufacturer-number field should remain exact.
Does a 4-20 mA output make transmitters interchangeable?
No. Review two-wire versus other power arrangements, voltage compliance, scaling, protection and calibration. The same nominal output span can be implemented by circuits with different installation and operating requirements.
Is the manufacturer lifecycle check a stock confirmation?
No. It describes the checked orderable status and may change. A supplier must separately confirm its proposed quantity, lot evidence, price and delivery terms in a dated offer before a purchaser can rely on them.
Request an RFQ review for XTR116U/2K5
Sources
- Texas Instruments XTR116 product information (checked 2026-10-02)
- Texas Instruments XTR116U ordering and package information (checked 2026-10-02)