Photo | Mfr. Part # | Availability | Quantity | Datasheet | RoHs | Series | Packaging | Product Status | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 | Power (Watts) | Applications | Voltage - Isolation | Operating Temperature | Features | Mounting Type | Size / Dimension |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
1010567CHCOREL-185-3001 CHCO |
50 |
|
![]() Datasheet |
![]() |
REL-185 (185W) | Box | Active | Enclosed | 3 | 85 ~ 264 VAC | 5V | 12V | - | -12V | - | - | 20 A | 5 A | 3 A | - | - | - | 185W | Industrial, ITE (Commercial), Laboratory, Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 6.25" L x 3.96" W x 1.48" H (156.8mm x 100.5mm x 37.6mm) |
![]() |
1010568CHCOREL-185-3002 CHCO |
50 |
|
![]() Datasheet |
![]() |
REL-185 (185W) | Box | Active | Enclosed | 3 | 85 ~ 264 VAC | 5V | 15V | - | -15V | - | - | 20 A | 4 A | 3 A | - | - | - | 185W | Industrial, ITE (Commercial), Laboratory, Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 6.25" L x 3.96" W x 1.48" H (156.8mm x 100.5mm x 37.6mm) |
![]() |
ESS50-24AC/DC CONVERTER 24V 53W |
61 |
|
![]() Datasheet |
![]() |
ESS50 (50W) | Bulk | Active | Enclosed | 1 | 85 ~ 264 VAC, 110 ~ 350 VDC | 24V | - | - | - | - | - | 2.2 A | - | - | - | - | - | 53W | Industrial, ITE (Commercial) | 3 kV | -10°C ~ 71°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 4.33" L x 1.30" W x 3.11" H (110.0mm x 33.0mm x 79.0mm) |
![]() |
9EB85-230AC/DC CONVERTER |
499 |
|
![]() Datasheet |
![]() |
- | Bulk | Active | Enclosed | 1 | 210 ~ 250 VAC | 9V | - | - | - | - | - | 850 mA | - | - | - | - | - | - | ITE (Commercial) | - | -20°C ~ 71°C | Adjustable Output, Universal Input | Chassis Mount | 3.53" L x 2.53" W x 1.65" H (89.7mm x 64.3mm x 41.9mm) |
![]() |
20EB40-230AC/DC CONVERTER |
495 |
|
![]() Datasheet |
![]() |
- | Bulk | Active | Enclosed | 1 | 210 ~ 250 VAC | 20V | - | - | - | - | - | 400 mA | - | - | - | - | - | - | ITE (Commercial) | - | -20°C ~ 71°C | Adjustable Output, Universal Input | Chassis Mount | 3.53" L x 2.53" W x 1.65" H (89.7mm x 64.3mm x 41.9mm) |
|
PEC800-12-074NAAC/DC CONVERTER 12V 780W |
60 |
|
![]() Datasheet |
![]() |
PEC800 (800W) | Box | Active | Front End | 1 | 90 ~ 264 VAC, 180 ~ 300 VDC | 12V | - | - | - | - | - | 65 A | - | - | - | - | - | 780W | ITE (Commercial) | 3 kV | 0°C ~ 55°C | Adjustable Output, Load Sharing, Remote Sense, Standby Output, Universal Input | Rack Mount | 7.28" L x 2.89" W x 1.57" H (185.0mm x 73.5mm x 40.0mm) |
![]() |
1010560CHCOREL-185-4001 CHCO |
50 |
|
![]() Datasheet |
![]() |
REL-185 (185W) | Box | Active | Enclosed | 4 | 85 ~ 264 VAC | 3.3V | 5V | 12V | -12V | - | - | 20 A | 10 A | 2 A | 2 A | - | - | 185W | Industrial, ITE (Commercial), Laboratory, Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 6.25" L x 3.96" W x 1.48" H (156.8mm x 100.5mm x 37.6mm) |
![]() |
1011470CHCOREL-185-4010 CHCO |
50 |
|
![]() Datasheet |
![]() |
REL-185 (185W) | Box | Active | Enclosed | 4 | 85 ~ 264 VAC | 5V | -5V | 24V | -24V | - | - | 20 A | 10 A | 1 A | 1 A | - | - | 185W | Industrial, ITE (Commercial), Laboratory, Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 6.25" L x 3.96" W x 1.48" H (156.8mm x 100.5mm x 37.6mm) |
![]() |
1010566CHCOREL-185-4007 CHCO |
50 |
|
![]() Datasheet |
![]() |
REL-185 (185W) | Box | Active | Enclosed | 4 | 85 ~ 264 VAC | 5V | 24V | 15V | -15V | - | - | 20 A | 3 A | 2 A | 2 A | - | - | 185W | Industrial, ITE (Commercial), Laboratory, Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 6.25" L x 3.96" W x 1.48" H (156.8mm x 100.5mm x 37.6mm) |
![]() |
1011429CHCOREL-185-4009 CHCO |
50 |
|
![]() Datasheet |
![]() |
REL-185 (185W) | Box | Active | Enclosed | 4 | 85 ~ 264 VAC | 5V | 12V | 28V | 12V | - | - | 15 A | 4 A | 800 mA | 2 A | - | - | 185W | Industrial, ITE (Commercial), Laboratory, Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 6.25" L x 3.96" W x 1.48" H (156.8mm x 100.5mm x 37.6mm) |
![]() |
1010565CHCOREL-185-4006 CHCO |
50 |
|
![]() Datasheet |
![]() |
REL-185 (185W) | Box | Active | Enclosed | 4 | 85 ~ 264 VAC | 5V | 24V | 12V | -12V | - | - | 20 A | 3 A | 2 A | 2 A | - | - | 185W | Industrial, ITE (Commercial), Laboratory, Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 6.25" L x 3.96" W x 1.48" H (156.8mm x 100.5mm x 37.6mm) |
![]() |
1010561CHCOREL-185-4002 CHCO |
50 |
|
![]() Datasheet |
![]() |
REL-185 (185W) | Box | Active | Enclosed | 4 | 85 ~ 264 VAC | 5V | 3.3V | 12V | -12V | - | - | 20 A | 10 A | 2 A | 2 A | - | - | 185W | Industrial, ITE (Commercial), Laboratory, Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 6.25" L x 3.96" W x 1.48" H (156.8mm x 100.5mm x 37.6mm) |
![]() |
1010564CHCOREL-185-4005 CHCO |
50 |
|
![]() Datasheet |
![]() |
REL-185 (185W) | Box | Active | Enclosed | 4 | 85 ~ 264 VAC | 5V | -5V | 15V | -15V | - | - | 20 A | 10 A | 2 A | 2 A | - | - | 185W | Industrial, ITE (Commercial), Laboratory, Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 6.25" L x 3.96" W x 1.48" H (156.8mm x 100.5mm x 37.6mm) |
![]() |
1010563CHCOREL-185-4004 CHCO |
50 |
|
![]() Datasheet |
![]() |
REL-185 (185W) | Box | Active | Enclosed | 4 | 85 ~ 264 VAC | 5V | -5V | 12V | -12V | - | - | 20 A | 10 A | 2 A | 2 A | - | - | 185W | Industrial, ITE (Commercial), Laboratory, Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 6.25" L x 3.96" W x 1.48" H (156.8mm x 100.5mm x 37.6mm) |
![]() |
1010562CHCOREL-185-4003 CHCO |
50 |
|
![]() Datasheet |
![]() |
REL-185 (185W) | Box | Active | Enclosed | 4 | 85 ~ 264 VAC | 5V | 3.3V | 15V | -15V | - | - | 20 A | 10 A | 2 A | 2 A | - | - | 185W | Industrial, ITE (Commercial), Laboratory, Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 6.25" L x 3.96" W x 1.48" H (156.8mm x 100.5mm x 37.6mm) |
![]() |
VOF-280-24AC/DC CONVERTER 24V 168W |
4,354 |
|
![]() Datasheet |
![]() |
VOF-280 (280W) | Bulk | Obsolete | Open Frame | 1 | 90 ~ 277 VAC | 24V | - | - | - | - | - | 7 A | - | - | - | - | - | 168W (280W Forced Air) | ITE (Commercial) | 3 kV | -20°C ~ 70°C (With Derating) | Adjustable Output, PFC, Standby Output, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.38" H (127.0mm x 76.2mm x 35.0mm) |
![]() |
VOF-280-12AC/DC CONVERTER 12V 168W |
3,805 |
|
![]() Datasheet |
![]() |
VOF-280 (280W) | Bulk | Obsolete | Open Frame | 1 | 90 ~ 277 VAC | 12V | - | - | - | - | - | 14 A | - | - | - | - | - | 168W (280W Forced Air) | ITE (Commercial) | 3 kV | -20°C ~ 70°C (With Derating) | Adjustable Output, PFC, Standby Output, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.38" H (127.0mm x 76.2mm x 35.0mm) |
![]() |
VOF-280-15AC/DC CONVERTER 15V 168W |
3,965 |
|
![]() Datasheet |
![]() |
VOF-280 (280W) | Bulk | Obsolete | Open Frame | 1 | 90 ~ 277 VAC | 15V | - | - | - | - | - | 11.2 A | - | - | - | - | - | 168W (280W Forced Air) | ITE (Commercial) | 3 kV | -20°C ~ 70°C (With Derating) | Adjustable Output, PFC, Standby Output, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.38" H (127.0mm x 76.2mm x 35.0mm) |
![]() |
VOF-280-48AC/DC CONVERTER 48V 168W |
214 |
|
![]() Datasheet |
![]() |
VOF-280 (280W) | Bulk | Active | Open Frame | 1 | 90 ~ 277 VAC | 48V | - | - | - | - | - | 3.5 A | - | - | - | - | - | 168W (280W Forced Air) | ITE (Commercial) | 3 kV | -20°C ~ 70°C (With Derating) | Adjustable Output, PFC, Standby Output, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.38" H (127.0mm x 76.2mm x 35.0mm) |
![]() |
VOF-280-36AC/DC CONVERTER 36V 168W |
3,409 |
|
![]() Datasheet |
![]() |
VOF-280 (280W) | Bulk | Active | Open Frame | 1 | 90 ~ 277 VAC | 36V | - | - | - | - | - | 4.67 A | - | - | - | - | - | 168W (280W Forced Air) | ITE (Commercial) | 3 kV | -20°C ~ 70°C (With Derating) | Adjustable Output, PFC, Standby Output, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.38" H (127.0mm x 76.2mm x 35.0mm) |