Photo | Mfr. Part # | Availability | Quantity | Datasheet | RoHs | Series | Packaging | Product Status | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 | Power (Watts) | Applications | Voltage - Isolation | Operating Temperature | Features | Mounting Type | Size / Dimension |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
CX10S-HDGHDH-P-A-DK00000ACDC CNVT 5V 24V 48V 5V 48V 24V EXCELSYS / Advanced Energy |
3,780 |
|
![]() Datasheet |
![]() |
COOLX®1000 | Box | Active | Enclosed | 10 | 85 ~ 264 VAC | 5V | 24V | 48V | 24V | 24V | 5V | 6 A | 3 A | 4.17 A | 3 A | 3 A | 6 A | 820W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-HBCHCD-P-A-DK00000ACDC CNVT 48V 24V 5V 24V 12V 24V EXCELSYS / Advanced Energy |
3,682 |
|
![]() Datasheet |
![]() |
COOLX®1000 | Box | Active | Enclosed | 8 | 85 ~ 264 VAC | 5V | 24V | 12V | 24V | 5V | 24V | 6 A | 3 A | 15 A | 8.3 A | 6 A | 3 A | 980W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-0D000C-P-A-DK00000AC/DC CONVERTER 24V 48V 400W EXCELSYS / Advanced Energy |
2,070 |
|
![]() Datasheet |
![]() |
COOLX®1000 | Box | Active | Enclosed | 2 | 85 ~ 264 VAC | 48V | 24V | - | - | - | - | 4.17 A | 8.3 A | 8.3 A | - | - | - | 400W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-D0DDDD-P-A-DK00000AC/DC CONVERTER 5X48V 1000W EXCELSYS / Advanced Energy |
3,301 |
|
![]() Datasheet |
![]() |
COOLX®1000 | Box | Active | Enclosed | 5 | 85 ~ 264 VAC | 48V | 48V | 48V | 48V | 48V | - | 4.17 A | 4.17 A | 4.17 A | 4.17 A | 4.17 A | - | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-GGGHGH-P-A-DK00000AC/DC CONVERTER 5V 5X24V 5V 680W EXCELSYS / Advanced Energy |
2,296 |
|
![]() Datasheet |
![]() |
COOLX®1000 | Box | Active | Enclosed | 12 | 85 ~ 264 VAC | 24V | 24V | 24V | 24V | 24V | 24V | 3 A | 3 A | 3 A | 3 A | 3 A | 3 A | 680W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-GGGHHH-P-A-DK00000AC/DC CNVT 5V 24V 5V 3X24V 5V EXCELSYS / Advanced Energy |
2,575 |
|
![]() Datasheet |
![]() |
COOLX®1000 | Box | Active | Enclosed | 12 | 85 ~ 264 VAC | 24V | 24V | 24V | 24V | 24V | 24V | 3 A | 3 A | 3 A | 3 A | 3 A | 3 A | 660W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-GBBGBH-P-A-DK00000ACDC CNVT 5V 24V 12V 24V 12V 24V EXCELSYS / Advanced Energy |
3,988 |
|
![]() Datasheet |
![]() |
COOLX®1000 | Box | Active | Enclosed | 9 | 85 ~ 264 VAC | 24V | 24V | 12V | 12V | 24V | 24V | 3 A | 3 A | 15 A | 15 A | 3 A | 3 A | 880W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-DGGHCD-P-A-DK00000AC/DC CNVT 48V 24V 5V 4X24V 940W EXCELSYS / Advanced Energy |
4,216 |
|
![]() Datasheet |
![]() |
COOLX®1000 | Box | Active | Enclosed | 9 | 85 ~ 264 VAC | 48V | 24V | 24V | 24V | 24V | 5V | 4.17 A | 3 A | 3 A | 3 A | 3 A | 6 A | 940W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-GCGHHD-P-A-DK00000AC/DC CNVT 48V 5V 24V 5V 2X24V EXCELSYS / Advanced Energy |
4,115 |
|
![]() Datasheet |
![]() |
COOLX®1000 | Box | Active | Enclosed | 10 | 85 ~ 264 VAC | 24V | 24V | 24V | 24V | 24V | 5V | 3 A | 3 A | 8.3 A | 3 A | 3 A | 6 A | 840W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-BHHHHA-P-A-DK00000AC/DC CNVT 2X5V 24V 2X5V 2X24V EXCELSYS / Advanced Energy |
2,927 |
|
![]() Datasheet |
![]() |
COOLX®1000 | Box | Active | Enclosed | 10 | 85 ~ 264 VAC | 12V | 5V | 24V | 5V | 24V | 5V | 15 A | 6 A | 3 A | 6 A | 3 A | 6 A | 685W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |