Photo | Mfr. Part # | Availability | Quantity | Datasheet | RoHs | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
CTL2002FSENSOR CURRENT 100A, 150A, 200A |
3,923 |
|
![]() Datasheet |
![]() |
CTL | Module, Single Pass Through | Bulk | Active | AC | Transformer w/Conditioning | 100A, 150A, 200A (Selectable) | 1 | Ratiometric, 4mA ~ 20mA | - | 20Hz ~ 100Hz | - | ±0.5% | 24V | 300ms | 40mA | -20°C ~ 50°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
LTC 1000-SC/SP6TRANSDUCER |
5,789 |
|
- |
![]() |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
LTC 1000-TF/SP14TRANSDUCER |
5,175 |
|
- |
![]() |
LTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±1% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
LTC 600-T/SP16TRANSDUCER |
5,509 |
|
![]() Datasheet |
![]() |
LTC | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 600A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.7% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
LTC 600-T/SP10TRANSDUCER |
3,016 |
|
- |
![]() |
LTC | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±1.6% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
ISOBLOCK I-ST-1C (30A 10V)TRANSDUCER CURRENT 9-28VDC |
4,558 |
|
![]() Datasheet |
![]() |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 30A | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 2.8µs | - | -25°C ~ 70°C | - | - | - | DIN Rail | - |
![]() |
ISOBLOCK I-ST-1C (2A 10V)SHUNT BASED CURRENT SENSOR |
4,741 |
|
![]() Datasheet |
![]() |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 2A | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
![]() |
ISOBLOCK I-ST-1C (5A 5V)SHUNT BASED CURRENT SENSOR |
4,030 |
|
![]() Datasheet |
![]() |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 5A | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
![]() |
ISOBLOCK I-ST-1C (20A 5V)SHUNT BASED CURRENT SENSOR |
5,928 |
|
![]() Datasheet |
![]() |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 20A | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
![]() |
ISOBLOCK I-ST-1C (500MA 5V)SHUNT BASED CURRENT SENSOR |
5,547 |
|
![]() Datasheet |
![]() |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 500mA | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
![]() |
ISOBLOCK I-ST-1C (200MA 5V)SHUNT BASED CURRENT SENSOR |
3,952 |
|
![]() Datasheet |
![]() |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 200mA | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
![]() |
ISOBLOCK I-ST-1C (40A 5V)SHUNT BASED CURRENT SENSOR |
3,121 |
|
![]() Datasheet |
![]() |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 40A | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
![]() |
ISOBLOCK I-ST-1C (5MA 5V)SHUNT BASED CURRENT SENSOR |
3,749 |
|
![]() Datasheet |
![]() |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 5mA | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
![]() |
ISOBLOCK I-ST-1C (30MA 10V)SHUNT BASED CURRENT SENSOR |
3,384 |
|
![]() Datasheet |
![]() |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 30mA | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
![]() |
ISOBLOCK I-ST-1C (4A 10V)SHUNT BASED CURRENT SENSOR |
5,672 |
|
![]() Datasheet |
![]() |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 4A | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
![]() |
ISOBLOCK I-ST-1C (3MA 10V)SHUNT BASED CURRENT SENSOR |
3,203 |
|
![]() Datasheet |
![]() |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 3mA | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
![]() |
ISOBLOCK I-ST-1C (6MA 5V)SHUNT BASED CURRENT SENSOR |
5,005 |
|
![]() Datasheet |
![]() |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 6mA | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
![]() |
ISOBLOCK I-ST-1C (6MA 10V)SHUNT BASED CURRENT SENSOR |
3,411 |
|
![]() Datasheet |
![]() |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 6mA | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
![]() |
ISOBLOCK I-ST-1C (10MA 5V)SHUNT BASED CURRENT SENSOR |
5,045 |
|
![]() Datasheet |
![]() |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 10mA | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
![]() |
ISOBLOCK I-ST-1C (3A 5V)SHUNT BASED CURRENT SENSOR |
5,988 |
|
![]() Datasheet |
![]() |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 3A | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |