| Photo | Mfr. Part # | Availability | Quantity | Datasheet | RoHs | Series | Packaging | Product Status | Input Type | Number of Outputs | AC Voltage - Input | DC Voltage - Input (Min) | DC Voltage - Input (Max) | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Efficiency | Operating Temperature | Features | Approval Agency | Standard Number | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
                 
                 
                
                 | 
				
                    DPX60-24S15DC/DC DIN RAIL SUPPLY 15V 60W TDK-Lambda  |  
                10 | 
                
                     | 
                 
                  
                    
                       Datasheet  | 
                   DPX (60W) | Bulk | Active | DC | 1 | - | 18V | 36V | 15V | - | - | - | - | - | 4A | 60W | - | ITE (Commercial) | 85% | -40°C ~ 85°C | - | CE | - | |
                 
                 
                
                 | 
				
                    DPP480-24-3AC/DC DIN RAIL SUPPLY 24V 480W TDK-Lambda  |  
                22 | 
                
                     | 
                 
                  
                    
                       Datasheet  | 
                   DPP (480W) | Bulk | Not For New Designs | AC | 1 | 340 ~ 575 VAC (3 Phase) | - | - | 24V | - | - | - | - | - | 20A | 480W | 3 kV | ITE (Commercial) | 90% | -40°C ~ 71°C (With Derating) | Adjustable Output, Load Sharing | CE | - | |
                 
                 
                
                 | 
				
                    DRL30-12-1AC/DC DIN RAIL SUPPLY 12V 30W TDK-Lambda  |  
                75 | 
                
                     | 
                 
                  
                    
                       Datasheet  | 
                   DRL (10-100W) | Bulk | Active | AC or DC | 1 | 85 ~ 264 VAC | 120V | 373V | 12V | - | - | - | - | - | 2.1A | 30W | 3 kV | Hazardous Locations, ITE (Commercial) | 88% | -20°C ~ 71°C (With Derating) | Adjustable Output, Universal Input | CE | - | |
| 
                 
                 | 
				
                    CSW65-24/DAC/DC DIN RAIL SUPPLY 24V 65W TDK-Lambda  |  
                5 | 
                
                     | 
                 
                  
                    
                       Datasheet  | 
                   CSW65 (65W) | Box | Active | AC | 1 | 90 ~ 305 VAC | - | - | 24V | - | - | - | - | - | 2.71A | 65W | 3 kV | ITE (Commercial) | 89% | -10°C ~ 70°C (With Derating) | - | CE | - | |
| 
                 
                 | 
				
                    CSW65-54/DAC/DC DIN RAIL SUPPLY 54V 65W TDK-Lambda  |  
                4 | 
                
                     | 
                 
                  
                    
                       Datasheet  | 
                   CSW65 (65W) | Box | Active | AC | 1 | 90 ~ 305 VAC | - | - | 54V | - | - | - | - | - | 1.21A | 65W | 3 kV | ITE (Commercial) | 89% | -10°C ~ 70°C (With Derating) | - | CE | - | |
| 
                 
                 | 
				
                    CSW65-12/DAC/DC DIN RAIL SUPPLY 12V 65W TDK-Lambda  |  
                4 | 
                
                     | 
                 
                  
                    
                       Datasheet  | 
                   CSW65 (65W) | Box | Active | AC | 1 | 90 ~ 305 VAC | - | - | 12V | - | - | - | - | - | 5.42A | 65W | 3 kV | ITE (Commercial) | 89% | -10°C ~ 70°C (With Derating) | - | CE | - | |
| 
                 
                 | 
				
                    CSW65-48/DAC/DC DIN RAIL SUPPLY 48V 65W TDK-Lambda  |  
                4 | 
                
                     | 
                 
                  
                    
                       Datasheet  | 
                   CSW65 (65W) | Box | Active | AC | 1 | 90 ~ 305 VAC | - | - | 48V | - | - | - | - | - | 1.36A | 65W | 3 kV | ITE (Commercial) | 89% | -10°C ~ 70°C (With Derating) | - | CE | - | |
| 
                 
                 | 
				
                    CSW65-18/DAC/DC DIN RAIL SUPPLY 18V 65W TDK-Lambda  |  
                2 | 
                
                     | 
                 
                  
                    
                       Datasheet  | 
                   CSW65 (65W) | Box | Active | AC | 1 | 90 ~ 305 VAC | - | - | 18V | - | - | - | - | - | 3.62A | 65W | 3 kV | ITE (Commercial) | 89% | -10°C ~ 70°C (With Derating) | - | CE | - | |
| 
                 
                 | 
				
                    CSW65-15/DAC/DC DIN RAIL SUPPLY 15V 65W TDK-Lambda  |  
                2 | 
                
                     | 
                 
                  
                    
                       Datasheet  | 
                   CSW65 (65W) | Box | Active | AC | 1 | 90 ~ 305 VAC | - | - | 15V | - | - | - | - | - | 4.34A | 65W | 3 kV | ITE (Commercial) | 89% | -10°C ~ 70°C (With Derating) | - | CE | - | |
                 
                 
                
                 | 
				
                    DPP240-24-3AC/DC DIN RAIL SUPPLY 24V 240W TDK-Lambda  |  
                12 | 
                
                     | 
                 
                  
                    
                       Datasheet  | 
                   DPP (240W) | Bulk | Not For New Designs | AC | 1 | 340 ~ 575 VAC (3 Phase) | - | - | 24V | - | - | - | - | - | 10A | 240W | 3 kV | ITE (Commercial) | 90% | -40°C ~ 71°C (With Derating) | Adjustable Output, Load Sharing | CE | - |