Available 24/7 at SENICO ELECTRONICS INTL CO., LIMITED
    SENICO ELECTRONICS INTL CO., LIMITED

    Valves and Control

    Manufacturer Series Packaging Product Status Type Function Actuator Type Operating Pressure Orifice Diameter Fluid Type Connection Method For Use With/Related Products Mounting Type Features
































































































































































































































































































































































































































































































































































































































































































































    Reset All
    Apply All
    Result:
    Photo Mfr. Part # Availability Price Quantity Datasheet RoHs Series Packaging Product Status Type Function Actuator Type Operating Pressure Orifice Diameter Fluid Type Connection Method For Use With/Related Products Mounting Type Features
    VZBA-21/2

    VZBA-21/2"-WW-63-T-22-F0710-V4V4T-PP106-R-90-C

    BALL VALVE ACTUATOR UNIT

    Festo Corporation

    4,352
    RFQ
    VZBA-21/2

    Datasheet

    VZBA-21/2 VZBA Bulk Active Ball Valve - - 87 ~ 122 PSI (6 ~ 8.4 bar) - Air, Inert Gas, Liquid Threaded Control Valve Free Hanging (In-Line) -
    VZOA-3-1/4

    VZOA-3-1/4

    TIME DELAY VALVE

    Festo Corporation

    4,575
    RFQ
    VZOA-3-1/4

    Datasheet

    VZOA-3-1/4 VZOA Bulk Active Timer, Adjustable - - 0 ~ 145 PSI (0 ~ 10 bar) - Air Threaded G1/8" Control Valve Chassis Mount -
    VZA-3-1/4

    VZA-3-1/4

    TIME DELAY VALVE

    Festo Corporation

    4,818
    RFQ
    VZA-3-1/4

    Datasheet

    VZA-3-1/4 VZA Bulk Active Timer, Adjustable - - 0 ~ 145 PSI (0 ~ 10 bar) - Air Threaded G1/8" Control Valve Chassis Mount -
    VZBE-4-T-63-T-2-F1012-V15V16

    VZBE-4-T-63-T-2-F1012-V15V16

    BALL VALVE

    Festo Corporation

    2,368
    RFQ

    -

    VZBE-4-T-63-T-2-F1012-V15V16 VZBE Bulk Active Ball Valve 2/2 - - - Air, Inert Gas, Liquid Threaded 4" NPT Control Valve Free Hanging (In-Line) -
    VZWF-L-M22C-G114-400-2AP4-10-R1

    VZWF-L-M22C-G114-400-2AP4-10-R1

    SOLENOID VALVE

    Festo Corporation

    4,383
    RFQ
    VZWF-L-M22C-G114-400-2AP4-10-R1

    Datasheet

    VZWF-L-M22C-G114-400-2AP4-10-R1 VZWF Bulk Active Solenoid Valve 2/2 Normally Closed - - - Air, Inert Gas, Liquid Threaded G1-1/4" Solenoid Valve Free Hanging (In-Line) -
    VZWF-L-M22C-G114-400-3AP4-10-R1

    VZWF-L-M22C-G114-400-3AP4-10-R1

    SOLENOID VALVE

    Festo Corporation

    3,812
    RFQ
    VZWF-L-M22C-G114-400-3AP4-10-R1

    Datasheet

    VZWF-L-M22C-G114-400-3AP4-10-R1 VZWF Bulk Active Solenoid Valve 2/2 Normally Closed - - - Air, Inert Gas, Liquid Threaded G1-1/4" Solenoid Valve Free Hanging (In-Line) -
    VZWF-L-M22C-G112-400-2AP4-10-R1

    VZWF-L-M22C-G112-400-2AP4-10-R1

    SOLENOID VALVE

    Festo Corporation

    3,913
    RFQ
    VZWF-L-M22C-G112-400-2AP4-10-R1

    Datasheet

    VZWF-L-M22C-G112-400-2AP4-10-R1 VZWF Bulk Active Solenoid Valve 2/2 Normally Closed - - - Air, Inert Gas, Liquid Threaded G1-1/2" Solenoid Valve Free Hanging (In-Line) -
    VZWF-L-M22C-G112-400-3AP4-10-R1

    VZWF-L-M22C-G112-400-3AP4-10-R1

    SOLENOID VALVE

    Festo Corporation

    3,130
    RFQ
    VZWF-L-M22C-G112-400-3AP4-10-R1

    Datasheet

    VZWF-L-M22C-G112-400-3AP4-10-R1 VZWF Bulk Active Solenoid Valve 2/2 Normally Closed - - - Air, Inert Gas, Liquid Threaded G1-1/2" Solenoid Valve Free Hanging (In-Line) -
    VZWF-L-M22C-N112-400-1P4-10-R1

    VZWF-L-M22C-N112-400-1P4-10-R1

    SOLENOID VALVE

    Festo Corporation

    4,907
    RFQ
    VZWF-L-M22C-N112-400-1P4-10-R1

    Datasheet

    VZWF-L-M22C-N112-400-1P4-10-R1 VZWF Bulk Active Solenoid Valve 2/2 Normally Closed - - - Air, Inert Gas, Liquid Threaded 1-1/2" NPT Solenoid Valve Free Hanging (In-Line) -
    VZWF-L-M22C-G112-400-1P4-10-R1

    VZWF-L-M22C-G112-400-1P4-10-R1

    SOLENOID VALVE

    Festo Corporation

    4,147
    RFQ
    VZWF-L-M22C-G112-400-1P4-10-R1

    Datasheet

    VZWF-L-M22C-G112-400-1P4-10-R1 VZWF Bulk Active Solenoid Valve 2/2 Normally Closed - - - Air, Inert Gas, Liquid Threaded G1-1/2" Solenoid Valve Free Hanging (In-Line) -
    VZWF-L-M22C-N112-400-3AP4-10-R1

    VZWF-L-M22C-N112-400-3AP4-10-R1

    SOLENOID VALVE

    Festo Corporation

    4,015
    RFQ
    VZWF-L-M22C-N112-400-3AP4-10-R1

    Datasheet

    VZWF-L-M22C-N112-400-3AP4-10-R1 VZWF Bulk Active Solenoid Valve 2/2 Normally Closed - - - Air, Inert Gas, Liquid Threaded 1-1/2" NPT Solenoid Valve Free Hanging (In-Line) -
    VZWF-L-M22C-N112-400-2AP4-10-R1

    VZWF-L-M22C-N112-400-2AP4-10-R1

    SOLENOID VALVE

    Festo Corporation

    2,635
    RFQ
    VZWF-L-M22C-N112-400-2AP4-10-R1

    Datasheet

    VZWF-L-M22C-N112-400-2AP4-10-R1 VZWF Bulk Active Solenoid Valve 2/2 Normally Closed - - - Air, Inert Gas, Liquid Threaded 1-1/2" NPT Solenoid Valve Free Hanging (In-Line) -
    VZWF-L-M22C-N114-400-3AP4-10-R1

    VZWF-L-M22C-N114-400-3AP4-10-R1

    SOLENOID VALVE

    Festo Corporation

    2,129
    RFQ
    VZWF-L-M22C-N114-400-3AP4-10-R1

    Datasheet

    VZWF-L-M22C-N114-400-3AP4-10-R1 VZWF Bulk Active Solenoid Valve 2/2 Normally Closed - - - Air, Inert Gas, Liquid Threaded 1-1/4" NPT Solenoid Valve Free Hanging (In-Line) -
    VZWF-L-M22C-N114-400-1P4-10-R1

    VZWF-L-M22C-N114-400-1P4-10-R1

    SOLENOID VALVE

    Festo Corporation

    3,739
    RFQ
    VZWF-L-M22C-N114-400-1P4-10-R1

    Datasheet

    VZWF-L-M22C-N114-400-1P4-10-R1 VZWF Bulk Active Solenoid Valve 2/2 Normally Closed - - - Air, Inert Gas, Liquid Threaded 1-1/4" NPT Solenoid Valve Free Hanging (In-Line) -
    VZWF-L-M22C-G114-400-1P4-10-R1

    VZWF-L-M22C-G114-400-1P4-10-R1

    SOLENOID VALVE

    Festo Corporation

    4,307
    RFQ
    VZWF-L-M22C-G114-400-1P4-10-R1

    Datasheet

    VZWF-L-M22C-G114-400-1P4-10-R1 VZWF Bulk Active Solenoid Valve 2/2 Normally Closed - - - Air, Inert Gas, Liquid Threaded G1-1/4" Solenoid Valve Free Hanging (In-Line) -
    VZWF-L-M22C-N114-400-2AP4-10-R1

    VZWF-L-M22C-N114-400-2AP4-10-R1

    SOLENOID VALVE

    Festo Corporation

    2,321
    RFQ
    VZWF-L-M22C-N114-400-2AP4-10-R1

    Datasheet

    VZWF-L-M22C-N114-400-2AP4-10-R1 VZWF Bulk Active Solenoid Valve 2/2 Normally Closed - - - Air, Inert Gas, Liquid Threaded 1-1/4" NPT Solenoid Valve Free Hanging (In-Line) -
    JMFH-5-1/8-NPT-72VDC -SA

    JMFH-5-1/8-NPT-72VDC -SA

    SOLENOID VALVE

    Festo Corporation

    2,683
    RFQ

    -

    JMFH-5-1/8-NPT-72VDC -SA - Bulk Active - - - - - - - - - -
    VABF-S4-2-V2B1-G38-CB-VL-20-A

    VABF-S4-2-V2B1-G38-CB-VL-20-A

    VACUUM GENERATOR

    Festo Corporation

    4,450
    RFQ

    -

    VABF-S4-2-V2B1-G38-CB-VL-20-A - Bulk Active Vacuum Generator 5/3 - 58 ~ 116 PSI (4 ~ 8 bar) - Air Threaded Control Valve Chassis Mount Supply Voltage 21.6 ~ 30VDC
    VABF-S4-2-V2B1-G38-CB-VH-20-A

    VABF-S4-2-V2B1-G38-CB-VH-20-A

    VACUUM GENERATOR

    Festo Corporation

    3,204
    RFQ

    -

    VABF-S4-2-V2B1-G38-CB-VH-20-A - Bulk Active Vacuum Generator 5/3 - 58 ~ 116 PSI (4 ~ 8 bar) - Air Threaded Control Valve Chassis Mount Supply Voltage 21.6 ~ 30VDC
    VABF-S4-2-V2B1-G38-CB-VH-20-AP

    VABF-S4-2-V2B1-G38-CB-VH-20-AP

    VACUUM GENERATOR

    Festo Corporation

    3,669
    RFQ

    -

    VABF-S4-2-V2B1-G38-CB-VH-20-AP - Bulk Active Vacuum Generator 5/3 - 58 ~ 116 PSI (4 ~ 8 bar) - Air Threaded Control Valve Chassis Mount Supply Voltage 21.6 ~ 30VDC
    Total 7416 Record«Prev1... 353354355356357358359360...371Next»
    HOME

    HOME

    PRODUCT

    PRODUCT

    PHONE

    PHONE

    USER

    USER