Photo | Mfr. Part # | Availability | Quantity | Datasheet | RoHs | Series | Packaging | Product Status | Type | Function | Actuator Type | Operating Pressure | Orifice Diameter | Fluid Type | Connection Method | For Use With/Related Products | Mounting Type | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
HGL-3/8-QS-10PILOTED CHECK VALVE Festo Corporation |
2 |
|
![]() Datasheet |
![]() |
- | Bulk | Active | Non-Return Valve (Check Valve) | - | - | 7 ~ 145 PSI (0.5 ~ 10 bar) | - | Air, Inert Gas, Liquid | Threaded | - | Sub-Base Mount | - |
![]() |
VUVS-LK30-B52-D-G38-1B2-SSOLENOID VALVE Festo Corporation |
16 |
|
![]() Datasheet |
![]() |
- | Bulk | Active | Solenoid Valve | - | - | 22 ~ 116 PSI (1.5 ~ 8 bar) | - | Air, Inert Gas, Liquid | Threaded | - | Sub-Base Mount | Supply Voltage 24VDC |
![]() |
VUVS-L30-B52-D-N38-F8SOLENOID VALVE Festo Corporation |
5 |
|
![]() Datasheet |
![]() |
- | Bulk | Active | Solenoid Valve | - | - | 22 ~ 145 PSI (1.5 ~ 10 bar) | - | Air, Inert Gas, Liquid | Threaded | - | Sub-Base Mount | - |
![]() |
VZWF-B-L-M22C-N14-135-1P4-10SOLENOID VALVE Festo Corporation |
3 |
|
![]() Datasheet |
![]() |
- | Bulk | Active | Solenoid Valve | - | - | - | - | Air, Inert Gas, Liquid | Threaded | - | Free Hanging (In-Line) | - |
![]() |
VUVG-L18-T32C-AT-G14-1R8LSOLENOID VALVE Festo Corporation |
9 |
|
![]() Datasheet |
![]() |
- | Bulk | Active | Solenoid Valve | 3/2 Normally Closed | - | 22 ~ 116 PSI (1.5 ~ 8 bar) | - | Air, Inert Gas, Liquid | Threaded | - | Sub-Base Mount | Supply Voltage 24VDC |
![]() |
VZBE-11/2-T-63-D-2-M-V15V15BALL VALVE Festo Corporation |
2 |
|
![]() Datasheet |
![]() |
- | Bulk | Active | Control Valve, Maintained | 2/2 | - | - | - | Air, Inert Gas, Liquid | Threaded | - | Free Hanging (In-Line) | - |
![]() |
MS4N-EE-1/4-10V24ON-OFF VALVE Festo Corporation |
2 |
|
![]() Datasheet |
![]() |
- | Bulk | Active | Control Valve, Maintained | 3/2 Normally Closed | - | 58 ~ 145 PSI (4 ~ 10 bar) | - | Air, Inert Gas, Liquid | Threaded | - | Sub-Base Mount | - |
![]() |
VSVA-B-M52-AH-A2-1R5LSOLENOID VALVE Festo Corporation |
10 |
|
![]() Datasheet |
![]() |
- | Bulk | Active | Solenoid Valve | - | - | 44 ~ 116 PSI (3 ~ 8 bar) | - | Air, Inert Gas, Liquid | Threaded | - | Sub-Base Mount | Supply Voltage 24VDC |
![]() |
VSVA-B-M52-MD-D1-1R5LSOLENOID VALVE Festo Corporation |
4 |
|
![]() Datasheet |
![]() |
- | Bulk | Active | Solenoid Valve | - | - | 44 ~ 145 PSI (3 ~ 10 bar) | - | Air, Inert Gas, Liquid | Threaded | - | Sub-Base Mount | Supply Voltage 24VDC |
![]() |
VZXF-L-M22C-M-B-N12-120-H3B1-50-16ANGLE SEAT VALVE Festo Corporation |
2 |
|
![]() Datasheet |
![]() |
- | Bulk | Active | Control Valve, Maintained | 2/2 | - | 87 ~ 145 PSI (6 ~ 10 bar) | - | Air, Inert Gas, Liquid | Threaded | - | Free Hanging (In-Line) | - |