| Photo | Mfr. Part # | Availability | Quantity | Datasheet | RoHs | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
FLLE2013ARMDLINE FILTER 300VAC/VDC 13A CHASS |
21,461 |
|
Datasheet |
FLLE2-R | Bulk | Last Time Buy | Single Phase | Two Stage | 300V | 300V | - | - | 13 A | 50/60Hz | Medical | ENEC, UR | -25°C ~ 100°C | Chassis Mount | Wire Leads | 600µH | |
|
AMI-28B-16-3LINE FILTER 250VAC 16A CHASS MNT |
14,481 |
|
- |
AMI-28 | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 16 A | DC ~ 400Hz | Medical | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect, Threaded Post (M4), Wire Leads | 2.84mH | |
|
AMI-28-16-6LINE FILTER 250VAC 16A CHASS MNT |
38,024 |
|
- |
AMI-28 | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 16 A | DC ~ 400Hz | General Purpose | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect, Threaded Post (M4), Wire Leads | 2.84mH | |
|
|
FN2450B-6-61LINE FILTER 250VAC 6A CHASS MNT |
16,673 |
|
Datasheet |
FN 2450 | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 6 A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | 10.5mH | |
|
1KESS1BFPWDMLINE FILTER 520VAC 1A CHASS MNT |
39,295 |
|
Datasheet |
KES | Box | Active | Three Phase (Wye) | Single Stage | - | 520V | - | - | 1 A | 50 ~ 60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Quick Connect | - | |
|
FLLE2013ARDDLINE FILTER 300VAC/VDC 13A CHASS |
16,453 |
|
Datasheet |
FLLE2-R | Bulk | Last Time Buy | Single Phase | Two Stage | 300V | 300V | - | - | 13 A | 50/60Hz | General Purpose | ENEC, UR | -25°C ~ 100°C | Chassis Mount | Wire Leads | 600µH | |
|
06DRPS4E(D)LINE FILTER 250VAC 6A CHASS MNT |
34,381 |
|
Datasheet |
DRP | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 6 A | 50/60Hz | General Purpose | cURus, ENEC | - | Chassis Mount | Terminal Block | 26mH | |
|
AMI-27A-16-3LINE FILTER 250VAC 16A CHASS MNT |
32,548 |
|
Datasheet |
AMI-27 | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 16 A | DC ~ 400Hz | Safety | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect, Threaded Post (M4), Wire Leads | 5.6mH | |
|
3-143-615LINE FILTER 250VAC 30A CHASS MNT |
49,595 |
|
Datasheet |
FMAB NEO | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 30 A | 50/60Hz | Medical | CE, cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Quick Connect | - | |
|
AMI-27B-16-3LINE FILTER 250VAC 16A CHASS MNT |
20,330 |
|
Datasheet |
AMI-27 | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 16 A | DC ~ 400Hz | Medical | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect, Threaded Post (M4), Wire Leads | 5.6mH | |
|
FN9675-3-06LINE FILTER 250VAC 3A CHASS MNT |
22,868 |
|
Datasheet |
FN 9675 | Tray | Obsolete | Single Phase | Single Stage | - | 250V | - | - | 3 A | DC ~ 400Hz | General Purpose | CSA, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 18mH | |
|
NBC-16-102LINE FILTER 250VAC/VDC 16A CHASS |
43,348 |
|
Datasheet |
NBC | Box | Active | Single Phase | Two Stage | 250V | 250V | 250 V | - | 16 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - | |
|
NBM-16-101LINE FILTER 250VAC/VDC 16A CHASS |
18,134 |
|
Datasheet |
NBM | Box | Active | Single Phase | Two Stage | 250V | 250V | 250 V | - | 16 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - | |
|
NBM-16-331LINE FILTER 250VAC/VDC 16A CHASS |
30,629 |
|
Datasheet |
NBM | Box | Active | Single Phase | Two Stage | 250V | 250V | 250 V | - | 16 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - | |
|
NAC-30-102-DLINE FILTER 250VAC/VDC 30A DIN |
48,742 |
|
Datasheet |
NAC | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 30 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - | |
|
NAC-30-222-DLINE FILTER 250VAC/VDC 30A DIN |
21,821 |
|
Datasheet |
NAC | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 30 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - | |
|
NAC-30-332-DLINE FILTER 250VAC/VDC 30A DIN |
32,880 |
|
Datasheet |
NAC | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 30 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - | |
|
NAC-30-472-DLINE FILTER 250VAC/VDC 30A DIN |
48,936 |
|
Datasheet |
NAC | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 30 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - | |
|
NAC-30-681-DLINE FILTER 250VAC/VDC 30A DIN |
16,037 |
|
Datasheet |
NAC | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 30 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - | |
|
NAM-30-000-DLINE FILTER 250VAC/VDC 30A DIN |
43,380 |
|
Datasheet |
NAM | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 30 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - |