| Photo | Mfr. Part # | Availability | Quantity | Datasheet | RoHs | Series | Packaging | Product Status | Type | Form | Number of Poles | Voltage - Continuous Operating (Max) (MCOV) | Current - Discharge (Nom) (8/20µS) | Current - Discharge (Max) (8/20µS) | Operating Temperature | Voltage - Protection Rating (VPR) | Voltage - Protection Level (VP) (2416) | Operating Temperature | Features | Mounting Type | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
SPD160480Y3J-NDSPD TYPE 2 640VAC MCOV 1 POLE |
3,248 |
|
- |
SPD | Bulk | Active | Type 2 | Module Only | 1 | 640VAC | 20 kA | 160 kA | 200 kA | 1.8 kV | - | -40°C ~ 50°C | Remote Signaling Contacts | Chassis Mount | cURus, UL | |
|
SPD160480Y3GSPD TYPE 2 640VAC MCOV 1 POLE |
3,142 |
|
- |
SPD | Bulk | Active | Type 2 | Module Only | 1 | 640VAC | 20 kA | 160 kA | 200 kA | 2 kV | - | -40°C ~ 50°C | Visual Life Indicator | Chassis Mount | cULus, UL | |
|
SPD160480D3CSPD TYPE 2 640VAC MCOV 1 POLE |
5,968 |
|
- |
SPD | Bulk | Active | Type 2 | Module Only | 1 | 640VAC | 20 kA | 160 kA | 200 kA | 2.5 kV | - | -40°C ~ 50°C | Visual Life Indicator | Chassis Mount | cULus, UL | |
|
BSPD200600Y3PSPD TYPE 2 200V MCOV 1 POLE |
5,410 |
|
- |
BSPD | Bulk | Active | Type 2 | Base + Module | 1 | 200V | 20 kA | - | 200 kA | 2.5 kV | - | -40°C ~ 50°C | Thermally Protected | Chassis Mount | CSA, UL | |
|
BSPD200480Y3PSPD TYPE 2 200V MCOV 1 POLE |
3,146 |
|
- |
BSPD | Bulk | Active | Type 2 | Base + Module | 1 | 200V | 20 kA | - | 200 kA | 2.5 kV | - | -40°C ~ 50°C | Thermally Protected | Chassis Mount | CSA, UL | |
|
SSP01SBA16DSPD TYPE 1 150V MCOV 1 POLE |
5,503 |
|
Datasheet |
- | Box | Active | Type 1 | Module Only | 1 | 150V | 20 kA | - | 200 kA | - | - | - | - | DIN Rail | - | |
|
SSP04EMA12DSPD 320V MCOV 1 POLE |
3,075 |
|
Datasheet |
- | Box | Active | - | Module Only | 1 | 320V | 20 kA | - | 200 kA | - | - | - | - | DIN Rail | - | |
|
SPD160230L3CSPD TYPE 2 MCOV 1 POLE |
4,871 |
|
- |
SPD | Bulk | Active | Type 2 | Base + Module | 1 | - | 20 kA | 160 kA | 200 kA | - | - | -40°C ~ 50°C | Thermally Protected | Chassis Mount | cURus, UL | |
|
SPD160240H3CSPD TYPE 2 300V MCOV 1 POLE |
3,124 |
|
- |
SPD | Bulk | Active | Type 2 | Base + Module | 1 | 300V | 20 kA | 160 kA | 200 kA | - | - | -40°C ~ 50°C | Thermally Protected | Chassis Mount | cURus, UL | |
|
BSPA200600Y7PSPD TYPE 2 840VAC MCOV 1 POLE |
4,013 |
|
Datasheet |
BSPA | Bulk | Active | Type 2 | Module Only | 1 | 840VAC | 20 kA | - | 200 kA | 2.5 kV | - | -40°C ~ 60°C | Remote Signaling Contacts, Thermally Protected, Visual Life Indicator | Chassis Mount | CSA, UL | |
|
BSPA200600D7PSPD TYPE 2 840VAC MCOV 1 POLE |
4,690 |
|
Datasheet |
BSPA | Bulk | Active | Type 2 | Module Only | 1 | 840VAC | 20 kA | - | 200 kA | 2.5 kV | - | -40°C ~ 60°C | Remote Signaling Contacts, Thermally Protected, Visual Life Indicator | Chassis Mount | CSA, UL | |
|
SSP08EMA16SPD 420V MCOV 1 POLE |
5,412 |
|
Datasheet |
- | Box | Active | - | Module Only | 1 | 420V | 20 kA | - | 200 kA | - | - | - | - | DIN Rail | - | |
|
SPD100230L4MSPD 1 POLE |
3,986 |
|
- |
SPD | Bulk | Active | - | Base + Module | 1 | - | 20 kA | 100 kA | 200 kA | - | - | -40°C ~ 50°C | Thermally Protected | Chassis Mount | cURus, UL | |
|
SSP04EMA12FSPD 320V MCOV 1 POLE |
3,698 |
|
Datasheet |
- | Box | Active | - | Module Only | 1 | 320V | 20 kA | - | 200 kA | - | - | - | - | DIN Rail | - | |
|
SPD200208Y3LSPD TYPE 2 300V MCOV 1 POLE |
3,533 |
|
- |
SPD | Bulk | Active | Type 2 | Base + Module | 1 | 300V | 20 kA | 200 kA | 200 kA | - | - | -40°C ~ 50°C | Thermally Protected | Chassis Mount | cURus, UL | |
|
SPD200600Y3LSPD TYPE 2 840V MCOV 1 POLE |
3,570 |
|
- |
SPD | Bulk | Active | Type 2 | Base + Module | 1 | 840V | 20 kA | 200 kA | 200 kA | - | - | -40°C ~ 50°C | Thermally Protected | Chassis Mount | cURus, UL | |
|
SPD200220Y3LSPD TYPE 2 300V MCOV 1 POLE |
4,250 |
|
- |
SPD | Bulk | Active | Type 2 | Base + Module | 1 | 300V | 20 kA | 200 kA | 200 kA | - | - | -40°C ~ 50°C | Thermally Protected | Chassis Mount | cURus, UL | |
|
SPD200600D3LSPD TYPE 2 840V MCOV 1 POLE |
4,541 |
|
- |
SPD | Bulk | Active | Type 2 | Base + Module | 1 | 840V | 20 kA | 200 kA | 200 kA | - | - | -40°C ~ 50°C | Thermally Protected | Chassis Mount | cURus, UL | |
|
SPD200240S3LSPD TYPE 2 300V MCOV 1 POLE |
3,953 |
|
- |
SPD | Bulk | Active | Type 2 | Base + Module | 1 | 300V | 20 kA | 200 kA | 200 kA | - | - | -40°C ~ 50°C | Thermally Protected | Chassis Mount | cURus, UL | |
|
SPD200400Y3LSPD TYPE 2 640V MCOV 1 POLE |
3,144 |
|
- |
SPD | Bulk | Active | Type 2 | Base + Module | 1 | 640V | 20 kA | 200 kA | 200 kA | - | - | -40°C ~ 50°C | Thermally Protected | Chassis Mount | cURus, UL |